Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Database
Language
Document Type
Year range
1.
Vaccine ; 41(29): 4206-4211, 2023 06 29.
Article in English | MEDLINE | ID: covidwho-20230961

ABSTRACT

Heterologous boost regimens are being increasingly considered against SARS-CoV-2. We report results for the 32 of 45 participants in the Phase 1 CoV2-001 clinical trial (Kim et al., Int J Iinfect Dis 2023, 128:112-120) who elected to receive an EUA-approved SARS-CoV-2 mRNA vaccine 6 to 8 months following a two-dose primary vaccination with the GLS-5310 bi-cistronic DNA vaccine given intradermally and followed by application of suction using the GeneDerm device. Receipt of EUA-approved mRNA vaccines after GLS-5310 vaccination was well-tolerated, with no reported adverse events. Immune responses were enhanced such that binding antibody titers, neutralizing antibody titers, and T-cell responses increased 1,187-fold, 110-fold, and 2.9-fold, respectively. This paper is the first description of the immune responses following heterologous vaccination with a DNA primary series and mRNA boost.


Subject(s)
COVID-19 , Vaccines, DNA , Humans , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines , DNA , SARS-CoV-2 , Vaccination
2.
Int J Infect Dis ; 128: 112-120, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2242189

ABSTRACT

OBJECTIVES: The CoV2-001 phase I randomized trial evaluated the safety and immunogenicity of the GLS-5310 bi-cistronic DNA vaccine through 48 weeks of follow-up. DESIGN: A total of 45 vaccine-naïve participants were recruited between December 31, 2020, and March 30, 2021. GLS-5310, encoding for the SARS-CoV-2 spike and open reading frame 3a (ORF3a) proteins, was administered intradermally at 0.6 mg or 1.2 mg per dose, followed by application of the GeneDerm suction device as part of a two-dose regimen spaced either 8 or 12 weeks between vaccinations. RESULTS: GLS-5310 was well tolerated with no serious adverse events reported. Antibody and T cell responses were dose-independent. Anti-spike antibodies were induced in 95.5% of participants with an average geometric mean titer of ∼480 four weeks after vaccination and declined minimally through 48 weeks. Neutralizing antibodies were induced in 55.5% of participants with post-vaccination geometric mean titer of 28.4. T cell responses were induced in 97.8% of participants, averaging 716 site forming units/106 cells four weeks after vaccination, increasing to 1248 at week 24, and remaining greater than 1000 through 48 weeks. CONCLUSION: GLS-5310 administered with the GeneDerm suction device was well tolerated and induced high levels of binding antibodies and T-cell responses. Antibody responses were similar to other DNA vaccines, whereas T cell responses were many-fold greater than DNA and non-DNA vaccines.


Subject(s)
COVID-19 Vaccines , COVID-19 , Humans , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/prevention & control , SARS-CoV-2 , Suction , Viral Vaccines , COVID-19 Vaccines/administration & dosage
3.
Arch Toxicol ; 97(4): 1177-1189, 2023 04.
Article in English | MEDLINE | ID: covidwho-2209309

ABSTRACT

pGO-1002, a non-viral DNA vaccine that expresses both spike and ORF3a antigens of SARS-CoV-2, is undergoing phase 1 and phase 2a clinical trials in Korea and the US. A preclinical repeated-dose toxicity study in New Zealand white rabbits in compliance with Good Laboratory Practice (GLP) was conducted to assess the potential toxicity, local tolerance, and immunogenicity of the vaccine and GeneDerm suction device. The dose rate was 1.2 mg/head pGO-1002, and this was administered intradermally to a group of animals (eight animals/sex/group) three times at 2-week intervals, followed by a 4-week recovery period. After each administration, suction was applied to the injection site using the GeneDerm device. Mortality, clinical signs, body weight, food consumption, skin irritation, ophthalmology, body temperature, urinalysis, and clinical pathology were also monitored. Gross observations and histopathological evaluation were performed. Overall, pGO-1002 administration-related changes were confined to minor damage or changes at the injection site, increased spleen weight and minimal increased cellularity in white pulp. All changes of injection site were considered local inflammatory changes or pharmacological actions due to the vaccine with the changes in spleen considered consistent with vaccine-induced immune activation. All findings showed reversibility during the 4-week recovery period. Animals vaccinated with pGO-1002, administered by intradermal injection and followed by application of suction with GeneDerm, developed humoral and cellular responses against the SARS-CoV-2 antigens consistent with prior studies in rats. Collectively, it was concluded that the pGO-1002 vaccine was safe and effective under these experimental conditions and these data supported future human study of the vaccine, now known as GLS-5310, for clinical trial use.


Subject(s)
COVID-19 , Vaccines, DNA , Humans , Rabbits , Animals , Rats , SARS-CoV-2 , Injections, Intradermal , COVID-19/prevention & control , Suction
SELECTION OF CITATIONS
SEARCH DETAIL